Tender Details
Sydney’s “Metropolitan Water Plan 2004 - Meeting the Challenges – Securing Sydney’s water future”, is a document that was prepared by the NSW Department of Infrastructure, Planning and Natural Resources. It was issued in October 2004 and provides a 25-year strategy to secure Sydney’s water supply. One of a number of strategies to be initially implemented involves recovering the deep water from Nepean Dam to secure supply to the Illawarra and Warragamba Dam to secure supply for Sydney.
The following pre-qualified companies have been invited to submit a response.
Baulderstone Hornibrook Pty Ltd
John Holland Pty Ltd
Thiess Pty Ltd
Tender responses from these companies only will be accepted.
The following pre-qualified companies have been invited to submit a response.
Tender responses from these companies only will be accepted.
Location
NSW Regions: Illawarra, Sydney
RFT Type
Pre-Qualified / Invited - Only those directly invited to tender, may obtain an RFT for the purpose of lodging a tender response.
Generally an invitation from a pre-qualified register of approved tenderers who have the ability to undertake the particular work or type of work proposed, a limited number of service providers are known to carry out the work or service (or in emergency or other restricted situations). Tenderers have usually been pre-qualified, accredited, or selected for the type of work and financial range. Competitive bids called from a standing offer (panel / period) contracts would also use this type.
RFT Preview Document(s)
Related Records
- Contract Award Notices:
- 0402006 Baulderstone Hornibrook Pty Ltd
Additional Details / Instructions
The objective of the Nepean Dam DWSR project is to maintain water levels in Avon Dam above the operating level of the outlet structure by transferring water from Nepean Dam while allowing the maximum amount of space for capture of rainfall in the Nepean Dam. The Nepean Dam has the smallest storage and the largest catchment of the four dams in the upper Nepean catchment and as a result has the highest probability of spilling during a rainfall event.
Nepean Dam is the sixth largest of 21 storage dams operated by the SCA that supply bulk water to Sydney, Wollongong and the Blue Mountains. It is the highest of four large dams in the Upper Nepean catchment located south of Sydney and was completed in 1927. Its construction comprises a concrete gravity dam with a crest length of 216 m and a height of 81 m.
The construction of an interconnecting tunnel between Nepean Dam and Avon Dam was completed in 1972. The transfer ability of the tunnel is limited by a rock ledge at the Nepean Dam entrance of the tunnel. It is assumed that at the time of construction, the water level in the dam limited excavation to the tunnel invert. Although the dam water level is currently above this ledge the water will be unable to gravitate to Avon Dam once it lowers below this level. The dam has a storage capacity of 70.2 GL of which 29 GL is unable to be transferred through the tunnel. The flow of water into the tunnel is currently controlled by a sluice gate.
During the early 1990’s the existing spillway was deepened and the Nepean Dam wall was strengthened using rockfill buttressing excavated from the spillway site. Two 900mm concrete encased low level pipes were also extended from the lower valve house and connected to the new (now existing) pump station (WPS77). The station pumps raw water to the Nepean Water Filtration Plant located above the dam.
HARD COPIES OF THE TENDER DOCUMENT HAVE BEEN POSTED TO THE PRE-REGISTERED CONTRACTORS - A CD WAS SENT AS PART OF THIS - IT CONTAINS A VOLUME 3 OF THE TENDER DOCUMENT.
Documents available for this RFT (issued on 13/06/2005) :
Only a Soft copy is available. A CD of the whole set of docuents is not available
Obtaining the Documents:
First time visitors to this web site who wish to download or order documents will need to self-register on this web site to gain access to any documents.
An information file on the RFT can be viewed – download the file at the blue “View a Summary Document – free” link at the bottom of this page (ie. save target as).
Lodgement of tender:
Your completed tenders should be lodged as allowed in the RFT documents, however they may usually be lodged electronically via this web page.
As the tenderer you must be a registered user in this system. Click on the blue "LODGE A RESPONSE" link at the bottom of this page and follow the on-screen instructions.
PC Software Requirements:
To be able to open and read/view the downloaded files for this RFT you may require certain software to be installed on your PC:
An Internet connection to lodge completed responses.
This web site has been optimised for the Microsoft Internet Explorer and Netscape Navigator web browsers.
The minimum requirements are as follows – IE version 5.5 or later, Firefox 1.0, Netscape Navigator Ver 4.7 or later with Cipher Strength = 128bit. Suggested minimum monitor resolution is 800x600.
Your web browser MUST be set to accept cookies. You will not be able to Register or accesss the documents if cookies have not allowed.
The tenderer is responsible for the provision and installation of the necessary software
Having Problems?
Having problems with logging in, responding, downloading, opening or viewing files, please refer to the FAQ section under the On-line ?HELP button at the top of this page.
Nepean Dam is the sixth largest of 21 storage dams operated by the SCA that supply bulk water to Sydney, Wollongong and the Blue Mountains. It is the highest of four large dams in the Upper Nepean catchment located south of Sydney and was completed in 1927. Its construction comprises a concrete gravity dam with a crest length of 216 m and a height of 81 m.
The construction of an interconnecting tunnel between Nepean Dam and Avon Dam was completed in 1972. The transfer ability of the tunnel is limited by a rock ledge at the Nepean Dam entrance of the tunnel. It is assumed that at the time of construction, the water level in the dam limited excavation to the tunnel invert. Although the dam water level is currently above this ledge the water will be unable to gravitate to Avon Dam once it lowers below this level. The dam has a storage capacity of 70.2 GL of which 29 GL is unable to be transferred through the tunnel. The flow of water into the tunnel is currently controlled by a sluice gate.
During the early 1990’s the existing spillway was deepened and the Nepean Dam wall was strengthened using rockfill buttressing excavated from the spillway site. Two 900mm concrete encased low level pipes were also extended from the lower valve house and connected to the new (now existing) pump station (WPS77). The station pumps raw water to the Nepean Water Filtration Plant located above the dam.
HARD COPIES OF THE TENDER DOCUMENT HAVE BEEN POSTED TO THE PRE-REGISTERED CONTRACTORS - A CD WAS SENT AS PART OF THIS - IT CONTAINS A VOLUME 3 OF THE TENDER DOCUMENT.
Documents available for this RFT (issued on 13/06/2005) :
Only a Soft copy is available. A CD of the whole set of docuents is not available
Obtaining the Documents:
First time visitors to this web site who wish to download or order documents will need to self-register on this web site to gain access to any documents.
- A full soft copy of this RFT/EOI can be downloaded from this web site free of charge.
- To obtain the provided RFT document(s) you must download to your own computer all the files provided (including addenda), by clicking on the blue "DOWNLOAD A SOFT COPY" link at the bottom of this page and following the on-screen instructions.
An information file on the RFT can be viewed – download the file at the blue “View a Summary Document – free” link at the bottom of this page (ie. save target as).
Lodgement of tender:
Your completed tenders should be lodged as allowed in the RFT documents, however they may usually be lodged electronically via this web page.
As the tenderer you must be a registered user in this system. Click on the blue "LODGE A RESPONSE" link at the bottom of this page and follow the on-screen instructions.
PC Software Requirements:
To be able to open and read/view the downloaded files for this RFT you may require certain software to be installed on your PC:
- Adobe ® Acrobat Reader ® 5.0 (or more recent) - Please click here Adobe ® Acrobat Reader ® to be taken to a free download site now.
- WinZip ® 7.0 (or more recent) or equivalent - Please click here Winzip ® to be taken to a free evaluation download site now.
- Microsoft ® Word 97 (or more recent) or equivalent
- Microsoft ® Excel 97 (or more recent) or equivalent
The minimum requirements are as follows – IE version 5.5 or later, Firefox 1.0, Netscape Navigator Ver 4.7 or later with Cipher Strength = 128bit. Suggested minimum monitor resolution is 800x600.
Your web browser MUST be set to accept cookies. You will not be able to Register or accesss the documents if cookies have not allowed.
The tenderer is responsible for the provision and installation of the necessary software
Having Problems?
Having problems with logging in, responding, downloading, opening or viewing files, please refer to the FAQ section under the On-line ?HELP button at the top of this page.