Tender Details
· Provide advice on the extent and detail of bore testing around three (3) Underground Petroleum Storage Systems (UPSS) at Kiandra required to validate this site. The intention is to leave these tanks in-situ and fill with concrete slurry. Historical significance poses disturbance limitations on this site which will need to be considered in this process.
· Drill sufficient boreholes and undertake sampling to establish the sub-surface contamination conditions at the Kiandra UPSS site. The sampling should consist of soil tests and groundwater (if applicable).
· Validation of ten (10) UPSS and associated bowser and fuel lines are to be removed.
· Perform a visual site surface contamination inspection after the removal of the AST at the Yarrangobilly Hydro Plant and validate the removed fuel supply lines (15 metres) from the Hydro Plant to the AST.
· Classification of associated spoil material at each site.
· Where contamination is found, the contamination is to be removed, or an alternate management strategy is to be adopted.
· Preparation of reports on the results of the validation exercise for each individual site.
Location
RFT Type
Tender Respondents
Business Name | Trading Name | Address |
---|---|---|
Clearsafe | Clearsafe | PO Box 304 Unanderra NSW 2526 AUSTRALIA |
Coffey Environments Australia Pty Ltd | Coffey Environments Australia Pty Ltd | Level 1, 3 Rider Boulevard Rhodes NSW 2138 AUSTRALIA |
Douglas Partners Pty Ltd | - | 96 Hermitage Road West Ryde NSW 2114 AUSTRALIA |
Geo-Logix Pty Ltd | - | Unit 2309/4 Daydream Street Warriewood NSW 2102 AUSTRALIA |
GHD Pty Ltd | GHD Pty Ltd | Level 7 16 Marcus Clarke Street Canberra ACT 2601 AUSTRALIA |
Jeffery and Katauskas Pty Ltd | Environmental Investigation Services (EIS) | 115 Wicks Road Macquarie Park Sydney NSW 2113 AUSTRALIA |
SMEC Australia Pty Ltd | - | Level 6/76 Berry Street North Sydney NSW 2059 AUSTRALIA |
The Impax Group | - | 100 Williams Circuit DUBBO NSW 2830 AUSTRALIA |
WSP Environmental | WSP Environmental Pty Ltd | Level 1, 41 McLaren Street North Sydney NSW 2060 AUSTRALIA |
Air Lube & Lift Services P/L T/as Austank | - | 5 Sonia Street Carrum Downs VIC 3201 AUSTRALIA |
Additional Details / Instructions
A mandatory Tender Site Visit is to be held as follows:
Date: Tuesday 25 October 2011
Meeting Time: 10.30am
Meeting Place: NPWS Office
7a Adelong Rd
TUMUT NSW
Conduct of Meeting:
10.30 Meet at NPWS Office TUMUT
11.00 Blowering Works Depot
1215 Yarrangobilly Caves
1330 Rules Point
1400 Kiandra
1530 Lake Jindabyne Works Depot
1600 Kosciuszko Education Centre
Address for Lodgement
Estimated Timeframe for Delivery
Item |
Due Date |
Mandatory Site Visits |
25 October 2011 |
Tender Close |
18 November 2011 |
Contract Award |
9 December 2011 |
|
|
All Site Validation Reports presented to Principle |
2 March 2012 |